“RAJLAXMI” Pneumatic operated spot welding machine are offered in 15, 20 & 30 KVA models. All machines are made of steel fabricated rigid structures to eliminate the minutest spot deflections. Pneumatic spot welders are designed for high speed production jobs meets vast needs of metal fabrication industries including sheet metal components cross wire welding electro brazing, resistance heating etc.
SALIENT FEATURES
TRANSFORMER: Low leakage (high linkage) design, proper cooling and insulation including winding varnishing by vacuum pressurized impregnation to enhance reliability and service life.
TIME CURRENT CONTROL: Current setting from min. to max. can be done by 6 position off load tap switch & micro processor. based synchronous controller with 25 different programmers of setting is incorporated with these machine in order to obtain consistent and accurate weld results of the jobs.
COOLING: Electrodes and arms are provided with water cooling arrangement with hose connections. (Optional for 20 & 30 KVA Model)
ELECTRODES: One pair of 2 straight electrodes made from hardened copper-alloy is supplied with the equipment. Other type or spare electrodes can be supplied on specific orders.
Particulars | Pneumatic Spot Welding Machine | ||
Model | RE-15 | RE-20 | RE-30 |
KVA Rating @50% duty cycle (KVA) |
15 | 20 | 30 |
Input Supply (Volts) | 380 / 440 | 380 / 440 | 380 / 440 |
Phase | 2 | 2 | 2 |
Insulation Class | A | A | A |
Nomitaion Throat Clearance (MM) | 250 | 250 | 250 |
Throat Depth (CM) | 50 | 50 | 50 |
Max. Available short circuit current (Amps.) |
8500 | 10000 | 12000 |
Max Electrode Force @ 6 kg/cm2 |
450 | 450 | 450 |
Max. Upper Electrode Stroke (MM) |
50 | 50 | 50 |
Approx Dimensions in mm (H L W) |
840 410 1450 |
1100 500 1640 |
1100 500 1640 |
Weight With arm (Approx Kgs.) |
215 | 220 | 250 |
Cooling for Arms & Electrodes | Water | Water | Water |
Cooling | Natural Air | ||
Customer to provide the following services | |||
Size of main supply copper cable (MM2) | 16 | 16 | 25 |
Recommended switch rating (AMPS) | 25 | 35 | 75 |
Delayed Action Fuse Rating (AMPS) | 30 | 40 | 60 |
External Water Supply at Max Temp. 30C. (Lits/Min) |
6 | 7 | 7 |